sudo smartctl -a /dev/sda
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-10-amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: TOSHIBA MQ04ABF100
Serial Number: 29QIPABUT
LU WWN Device Id: 5 000039 912a0b29c
Firmware Version: 100002
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Form Factor: 2.5 inches
Zoned Device: Device managed zones
Device is: Not in smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Tue Jul 11 07:20:07 2023 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 25) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 120) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 173) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 128
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1386
5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 38
9 Power_On_Hours 0x0032 070 070 000 Old_age Always - 12044
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 4287
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 8219
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 68
193 Load_Cycle_Count 0x0032 096 096 000 Old_age Always - 46924
194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 33 (Min/Max 9/56)
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0032 071 071 000 Old_age Always - 11898
241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 70094411489
242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 87419984956
254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
ATA Error Count: 12525 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 12525 occurred at disk power-on lifetime: 12040 hours (501 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 38 a8 0c d0 40 Error: UNC at LBA = 0x00d00ca8 = 13634728
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 38 a8 0c d0 40 00 00:00:38.308 READ FPDMA QUEUED
ef 10 03 00 00 00 a0 00 00:00:38.307 SET FEATURES [Enable SATA feature]
ef 10 02 00 00 00 a0 00 00:00:38.306 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:00:38.306 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:00:38.305 IDENTIFY DEVICE
Error 12524 occurred at disk power-on lifetime: 12040 hours (501 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 40 a8 0c d0 40 Error: UNC at LBA = 0x00d00ca8 = 13634728
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 40 a8 0c d0 40 00 00:00:37.527 READ FPDMA QUEUED
ef 10 03 00 00 00 a0 00 00:00:37.526 SET FEATURES [Enable SATA feature]
ef 10 02 00 00 00 a0 00 00:00:37.526 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:00:37.525 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:00:37.525 IDENTIFY DEVICE
Error 12523 occurred at disk power-on lifetime: 12040 hours (501 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 30 a8 0c d0 40 Error: UNC at LBA = 0x00d00ca8 = 13634728
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 30 a8 0c d0 40 00 00:00:36.747 READ FPDMA QUEUED
ef 10 03 00 00 00 a0 00 00:00:36.746 SET FEATURES [Enable SATA feature]
ef 10 02 00 00 00 a0 00 00:00:36.746 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 e0 00 00:00:36.745 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 00 00 a0 00 00:00:36.744 IDENTIFY DEVICE
Error 12522 occurred at disk power-on lifetime: 12040 hours (501 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 80 a8 0c d0 40 Error: UNC at LBA = 0x00d00ca8 = 13634728
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 80 a8 0c d0 40 00 00:00:35.968 READ FPDMA QUEUED
60 08 78 a0 0c d0 40 00 00:00:35.957 READ FPDMA QUEUED
60 08 70 98 0c d0 40 00 00:00:35.945 READ FPDMA QUEUED
60 08 68 90 0c d0 40 00 00:00:35.945 READ FPDMA QUEUED
60 08 60 88 0c d0 40 00 00:00:35.945 READ FPDMA QUEUED
Error 12521 occurred at disk power-on lifetime: 12040 hours (501 days + 16 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 41 40 a8 0c d0 40 Error: UNC at LBA = 0x00d00ca8 = 13634728
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 40 00 09 d0 40 00 00:00:34.992 READ FPDMA QUEUED
60 08 38 00 09 90 40 00 00:00:34.991 READ FPDMA QUEUED
60 00 30 80 74 d0 40 00 00:00:34.991 READ FPDMA QUEUED
60 00 28 80 73 d0 40 00 00:00:34.990 READ FPDMA QUEUED
60 00 20 80 72 d0 40 00 00:00:34.989 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Aborted by host 90% 12040 -
# 2 Short offline Completed without error 00% 12040 -
# 3 Short offline Completed without error 00% 12040 -
# 4 Short offline Completed without error 00% 9834 -
# 5 Short offline Completed without error 00% 9487 -
# 6 Short offline Completed without error 00% 9170 -
# 7 Short offline Completed without error 00% 8835 -
# 8 Short offline Completed without error 00% 8504 -
# 9 Short offline Completed without error 00% 8207 -
#10 Short offline Completed without error 00% 7823 -
#11 Short offline Completed without error 00% 7423 -
#12 Short offline Completed without error 00% 6832 -
#13 Short offline Completed without error 00% 6568 -
#14 Short offline Completed without error 00% 5718 -
#15 Short offline Completed without error 00% 5273 -
#16 Short offline Completed without error 00% 4905 -
#17 Short offline Completed without error 00% 4774 -
#18 Short offline Completed without error 00% 4499 -
#19 Short offline Completed without error 00% 4193 -
#20 Short offline Completed without error 00% 3821 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.Editor is loading...