Untitled
unknown
powershell
a year ago
5.1 kB
0
Indexable
Never
Current configuration: ! version "7.2.2" switch-type "IBM Networking Operating System RackSwitch G8052" ! ! snmp-server community 1 index "ro" ! snmp-server read-community "RO" ! no system dhcp hostname "lenovoG8052-010" ! ! interface port 1 spanning-tree edge exit ! interface port 2 spanning-tree edge exit ! interface port 3 spanning-tree edge exit ! interface port 4 spanning-tree edge exit ! interface port 5 spanning-tree edge exit ! interface port 6 spanning-tree edge exit ! interface port 7 spanning-tree edge exit ! interface port 8 spanning-tree edge exit ! interface port 9 spanning-tree edge exit ! interface port 10 spanning-tree edge exit ! interface port 11 spanning-tree edge exit ! interface port 12 spanning-tree edge exit ! interface port 13 spanning-tree edge exit ! interface port 14 spanning-tree edge exit ! interface port 15 spanning-tree edge exit ! interface port 16 spanning-tree edge exit ! interface port 17 spanning-tree edge exit ! interface port 18 spanning-tree edge exit ! interface port 19 spanning-tree edge exit ! interface port 20 spanning-tree edge exit ! interface port 21 spanning-tree edge exit ! interface port 22 spanning-tree edge exit ! interface port 23 spanning-tree edge exit ! interface port 24 spanning-tree edge exit ! interface port 25 spanning-tree edge exit ! interface port 26 spanning-tree edge exit ! interface port 27 spanning-tree edge exit ! interface port 28 spanning-tree edge exit ! interface port 29 spanning-tree edge exit ! interface port 30 spanning-tree edge exit ! interface port 31 spanning-tree edge exit ! interface port 32 spanning-tree edge exit ! interface port 33 spanning-tree edge exit ! interface port 34 spanning-tree edge exit ! interface port 35 spanning-tree edge exit ! interface port 36 spanning-tree edge exit ! interface port 37 spanning-tree edge exit ! interface port 38 spanning-tree edge exit ! interface port 39 spanning-tree edge exit ! interface port 40 spanning-tree edge exit ! interface port 41 spanning-tree edge exit ! interface port 42 spanning-tree edge exit ! interface port 43 spanning-tree edge exit ! interface port 44 spanning-tree edge exit ! interface port 45 spanning-tree edge exit ! interface port 46 spanning-tree edge exit ! interface port 47 spanning-tree edge exit ! interface port 48 spanning-tree edge duplex full exit ! vlan 1 name "VLAN 1" ! ! ! ! ! ! ! ! ! ! interface ip 1 ip address 172.30.50.10 255.255.0.0 enable exit ! ! ! ! ! ! end lenovoG8052-010# sh ver lenovoG8052-010# sh version System Information at 9:22:56 Wed Jul 5, 2023 Time zone: America/US/Pacific Daylight Savings Time Status: Disabled IBM Networking Operating System RackSwitch G8052 Switch has been up for 1 day, 1 hour, 36 minutes and 53 seconds. Last boot: 8:01:52 Tue Jul 4, 2023 (power cycle) MAC address: a8:97:dc:f3:2c:00 IP (If 1) address: 172.30.50.10 Hardware Revision: Board Revision: Switch Serial No: Y01BCM4BK198 Hardware Part No: 00AY327 Spare Part No: 00AY327 Manufacturing date: 14/46 MTM: 7309HC2 ESN: MM12651 Software Version 7.2.2.0 (FLASH image1), active configuration. Temperature Top: 32 C Temperature Bottom: 27 C Temperature Fan Ctrl 88: 34 C Temperature Fan Ctrl 8a: 60 C Temperature Fan Ctrl 8c: 42 C Temperature Phy 0x01: 61 C Temperature Phy 0x09: 64 C Temperature Phy 0x11: 64 C Temperature Phy 0x21: 44 C Temperature Phy 0x29: 40 C Temperature Phy 0x31: 43 C Warning at 60 C and Recover at 80 C Fan 1 in Module 1: Not Installed Fan 2 in Module 1: Not Installed Fan 3 in Module 2: RPM= 8108 PWM= 90 ( 9%) Front-To-Back [N] Fan 4 in Module 2: RPM= 8463 PWM= 90 ( 9%) Front-To-Back [N] Fan 5 in Module 3: RPM= 7837 PWM= 90 ( 9%) Front-To-Back [N] Fan 6 in Module 3: RPM= 8437 PWM= 90 ( 9%) Front-To-Back [N] Fan 7 in Module 4: RPM= 7736 PWM= 90 ( 9%) Front-To-Back [N] Fan 8 in Module 4: RPM= 8503 PWM= 90 ( 9%) Front-To-Back [N] System Fan Airflow: Front-To-Back Power Supply 1: OK Power Supply 2: OK Power Faults: () Fan Faults: () Service Faults: ()