[srv30.zload][root@~] > smartctl -a /dev/sdd 
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.0-26-amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     ST18000NM000J-2TV103
Serial Number:    ZR5DFC3L
LU WWN Device Id: 5 000c50 0e6043eb6
Firmware Version: SN04
User Capacity:    18,000,207,937,536 bytes [18.0 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Form Factor:      3.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-4 (minor revision not indicated)
SATA Version is:  SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sun Jan 19 09:23:41 2025 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  575) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (1603) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x70bd) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   071   045   044    Pre-fail  Always       -       143336232
  3 Spin_Up_Time            0x0003   095   095   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       5
  5 Reallocated_Sector_Ct   0x0033   099   099   010    Pre-fail  Always       -       226
  7 Seek_Error_Rate         0x000f   090   060   045    Pre-fail  Always       -       916725440
  9 Power_On_Hours          0x0032   088   088   000    Old_age   Always       -       11181
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       5
 18 Unknown_Attribute       0x000b   100   100   050    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       109
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       1
190 Airflow_Temperature_Cel 0x0022   070   067   000    Old_age   Always       -       30 (Min/Max 26/33)
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       3
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       479
194 Temperature_Celsius     0x0022   030   040   000    Old_age   Always       -       30 (0 26 0 0 0)
197 Current_Pending_Sector  0x0012   099   098   000    Old_age   Always       -       260
198 Offline_Uncorrectable   0x0010   099   098   000    Old_age   Offline      -       260
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0023   100   100   001    Pre-fail  Always       -       0
240 Head_Flying_Hours       0x0000   100   100   000    Old_age   Offline      -       11128 (115 74 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       19011371984
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       3030941398256

SMART Error Log Version: 1
ATA Error Count: 26243 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 26243 occurred at disk power-on lifetime: 11181 hours (465 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 78 ff ff ff 4f 00  16d+06:47:30.818  READ FPDMA QUEUED
  60 00 98 ff ff ff 4f 00  16d+06:47:30.818  READ FPDMA QUEUED
  60 00 68 ff ff ff 4f 00  16d+06:47:30.818  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00  16d+06:47:30.785  READ FPDMA QUEUED
  60 00 f8 ff ff ff 4f 00  16d+06:47:30.785  READ FPDMA QUEUED

Error 26242 occurred at disk power-on lifetime: 11181 hours (465 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 80 ff ff ff 4f 00  16d+06:47:00.275  READ FPDMA QUEUED
  60 00 80 ff ff ff 4f 00  16d+06:47:00.275  READ FPDMA QUEUED
  60 00 40 ff ff ff 4f 00  16d+06:47:00.199  READ FPDMA QUEUED
  60 00 40 ff ff ff 4f 00  16d+06:47:00.196  READ FPDMA QUEUED
  60 00 c0 ff ff ff 4f 00  16d+06:47:00.196  READ FPDMA QUEUED

Error 26241 occurred at disk power-on lifetime: 11181 hours (465 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 00 ff ff ff 4f 00  16d+06:46:57.955  READ FPDMA QUEUED
  60 00 00 ff ff ff 4f 00  16d+06:46:57.955  READ FPDMA QUEUED
  60 00 00 ff ff ff 4f 00  16d+06:46:57.955  READ FPDMA QUEUED
  60 00 c0 ff ff ff 4f 00  16d+06:46:57.953  READ FPDMA QUEUED
  60 00 40 ff ff ff 4f 00  16d+06:46:57.953  READ FPDMA QUEUED

Error 26240 occurred at disk power-on lifetime: 11181 hours (465 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 00 ff ff ff 4f 00  16d+06:45:47.303  READ FPDMA QUEUED
  60 00 60 ff ff ff 4f 00  16d+06:45:45.825  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00  16d+06:45:45.816  READ FPDMA QUEUED
  60 00 f8 ff ff ff 4f 00  16d+06:45:45.816  READ FPDMA QUEUED
  60 00 00 ff ff ff 4f 00  16d+06:45:45.816  READ FPDMA QUEUED

Error 26239 occurred at disk power-on lifetime: 11181 hours (465 days + 21 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 48 ff ff ff 4f 00  16d+06:45:45.096  READ FPDMA QUEUED
  60 00 00 ff ff ff 4f 00  16d+06:45:45.083  READ FPDMA QUEUED
  60 00 00 ff ff ff 4f 00  16d+06:45:44.593  READ FPDMA QUEUED
  60 00 08 ff ff ff 4f 00  16d+06:45:44.284  READ FPDMA QUEUED
  60 00 20 ff ff ff 4f 00  16d+06:45:44.246  READ FPDMA QUEUED

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.